Difference between revisions of "MainPage:Nuclear:Summer2017:Casey"

From cua_phy
Jump to navigation Jump to search
Line 11: Line 11:
  
 
<h1> Summary of results at beginning of summer 2017 </h1>
 
<h1> Summary of results at beginning of summer 2017 </h1>
<p>I collected all of the Light Yield results for all crystals and found an average light yield for each crystal. The majority of the crystals had multiple trials, and I used those trials to calculate the least mean squared uncertainty. See link for example (). The solid blue line is the horizontal line of best fit through the data, indicating the average light yield of all crystals combined. The dotted red lines represent the lower and upper limits at 10 pe/MeV and 15 pe/MeV. All crystals except BTCP, J11, J17, J24, J29, J36, and SICCA 02 fall within the limits. </p>
+
<p>I collected all of the Light Yield results for all crystals and found an average light yield for each crystal. The majority of the crystals had multiple trials, and I used those trials to calculate the least mean squared uncertainty. See picture of calculations for example. The solid blue line is the horizontal line of best fit through the data, indicating the average light yield of all crystals combined. The dotted red lines represent the lower and upper limits at 10 pe/MeV and 15 pe/MeV. All crystals except BTCP, J11, J17, J24, J29, J36, and SICCA 02 fall within the limits. </p>
  
  
  
 
[[File:Average Light Yields of Crystals1.png|thumb|center|250px| ]]
 
[[File:Average Light Yields of Crystals1.png|thumb|center|250px| ]]
 +
[[File:Least Mean Squared Unc.png|thumb|center|250px|]]

Revision as of 11:59, 5 July 2017

Impact of surface and reflector on crystal light uniformity

Abstract

Text.

Introduction

Text.

Description of the crystal light yield measurements

Text.

Summary of results at beginning of summer 2017

I collected all of the Light Yield results for all crystals and found an average light yield for each crystal. The majority of the crystals had multiple trials, and I used those trials to calculate the least mean squared uncertainty. See picture of calculations for example. The solid blue line is the horizontal line of best fit through the data, indicating the average light yield of all crystals combined. The dotted red lines represent the lower and upper limits at 10 pe/MeV and 15 pe/MeV. All crystals except BTCP, J11, J17, J24, J29, J36, and SICCA 02 fall within the limits.


Average Light Yields of Crystals1.png
Least Mean Squared Unc.png