[[File:20170621 135238.jpg|thumb|center|250px| Initial setup to calibrate the accelerometer]]
 
[[File:20170621 135238.jpg|thumb|center|250px| Initial setup to calibrate the accelerometer]]
 +
 +
calibration of the accelerometer:
 +
 +
misalignment angle            measured gravity              deviation percentage
 +
 +
2.26245953203 degrees,  9.80764530293 m/s^2,  0.0816326530612 % for the x-axis
 +
 +
2.11138229046 degrees,  9.80665779414 m/s^2,  0.0714285714286 % for the y-axis
 +
 +
1.88511051001 degrees,  9.80530664911 m/s^2,  0.0510204081633 % for the z-axis
  
 
[[File:Vib1.png|thumb|center|250px| Initial result using the calibrated accelerometer sensor and the assembled mechanical setup of the crystal drawing prototype. The coordinate system is such that the z-axis and x-axis get to be parallel with gravity, while the y-axis is parallel to the shaft. The sampling rate was 100ms and the rotation setting was 3]]
 
[[File:Vib1.png|thumb|center|250px| Initial result using the calibrated accelerometer sensor and the assembled mechanical setup of the crystal drawing prototype. The coordinate system is such that the z-axis and x-axis get to be parallel with gravity, while the y-axis is parallel to the shaft. The sampling rate was 100ms and the rotation setting was 3]]

Revision as of 11:50, 28 June 2017

Commissioning of a crystal drawing system

Abstract

Text.

Introduction

Text.

Description of the crystal drawing apparatus

Text.

Vibration Studies

Text.

Initial setup to calibrate the accelerometer

calibration of the accelerometer:

misalignment angle measured gravity deviation percentage

2.26245953203 degrees, 9.80764530293 m/s^2, 0.0816326530612 % for the x-axis

2.11138229046 degrees, 9.80665779414 m/s^2, 0.0714285714286 % for the y-axis

1.88511051001 degrees, 9.80530664911 m/s^2, 0.0510204081633 % for the z-axis

Initial result using the calibrated accelerometer sensor and the assembled mechanical setup of the crystal drawing prototype. The coordinate system is such that the z-axis and x-axis get to be parallel with gravity, while the y-axis is parallel to the shaft. The sampling rate was 100ms and the rotation setting was 3


Rotation Studies

Text.


Calibration of the load cell

Text.