| 910 || 08/06/2012 || Laura || 9650 (BLAST) || -1.8 || Prototype Testing (Cosmic) || 9cm Aerogel run in the dark-box. Using separate HV sources. Tracker still shows two patches of events above the pedestal. Notice large error on fit of signal peak. || [[File:910.gif|frameless]]
 
| 910 || 08/06/2012 || Laura || 9650 (BLAST) || -1.8 || Prototype Testing (Cosmic) || 9cm Aerogel run in the dark-box. Using separate HV sources. Tracker still shows two patches of events above the pedestal. Notice large error on fit of signal peak. || [[File:910.gif|frameless]]
 +
|-
 +
| 911 || 08/06/2012 || Laura || 9650 (BLAST) || -1.8 || Prototype Testing (Cosmic) || 8cm Aerogel run in the dark-box. Using separate HV sources. Tracker still shows a patch of events above the pedestal. || [[File:911.gif|frameless]]
 +
|-
 +
| 912 || 08/07/2012 || Laura || 9650 (BLAST) || -1.8 || Prototype Testing (Cosmic) || 7cm Aerogel run in the dark-box. Using separate HV sources. Overnight run. Tracker: about 3 patches of signal above pedestal. Signal: mostly one signal peak (second very small patch at ~400 seems more like trailing peak) || [[File:912.gif|frameless]]
 +
|-
 +
| 913 || 08/08/2012 || Laura || 9650 (BLAST) || -1.8 || Prototype Testing (Cosmic) || 6cm Aerogel run in the dark-box. Using separate HV sources. 6 hour run. Seems to be too few data points and therefore a bad fit to the signal peak. Run 914 is the same but for a longer time. || [[File:913.gif|frameless]]
 +
|-
 +
| 914 || 08/06/2012 || Laura || 9650 (BLAST) || -1.8 || Prototype Testing (Cosmic) || 6cm Aerogel run in the dark-box. Using separate HV sources. Tracker: very small patch of signals between 400 and 600. || [[File:914.gif|frameless]]
 
|}
 
|}

Revision as of 15:17, 9 August 2012

⇐ Back to the PMT Characteristics page
⇒ Go to Summer 2012 work page

LogBook on the CODA data acquisition, at CUA

Page 3, [2], [1].

LogBook - Page 03
Run Number Date User PMT High Voltage Experiment Description and observations Image
910 08/06/2012 Laura 9650 (BLAST) -1.8 Prototype Testing (Cosmic) 9cm Aerogel run in the dark-box. Using separate HV sources. Tracker still shows two patches of events above the pedestal. Notice large error on fit of signal peak.
Error creating thumbnail: Unable to save thumbnail to destination
911 08/06/2012 Laura 9650 (BLAST) -1.8 Prototype Testing (Cosmic) 8cm Aerogel run in the dark-box. Using separate HV sources. Tracker still shows a patch of events above the pedestal.
Error creating thumbnail: Unable to save thumbnail to destination
912 08/07/2012 Laura 9650 (BLAST) -1.8 Prototype Testing (Cosmic) 7cm Aerogel run in the dark-box. Using separate HV sources. Overnight run. Tracker: about 3 patches of signal above pedestal. Signal: mostly one signal peak (second very small patch at ~400 seems more like trailing peak)
Error creating thumbnail: Unable to save thumbnail to destination
913 08/08/2012 Laura 9650 (BLAST) -1.8 Prototype Testing (Cosmic) 6cm Aerogel run in the dark-box. Using separate HV sources. 6 hour run. Seems to be too few data points and therefore a bad fit to the signal peak. Run 914 is the same but for a longer time.
Error creating thumbnail: Unable to save thumbnail to destination
914 08/06/2012 Laura 9650 (BLAST) -1.8 Prototype Testing (Cosmic) 6cm Aerogel run in the dark-box. Using separate HV sources. Tracker: very small patch of signals between 400 and 600.
Error creating thumbnail: Unable to save thumbnail to destination